Base, High

Model
 Number
Part
Number
Width
Inches/mm
Height
Inches/mm
Depth
Inches/mm
CAD

 BCD 250 UT-7035

20250135 00

8.98/228 10.24/260 4.13/105.0

The high base available in light gray, can be combined with different front elements. The high base has the following features: PCB slots, fixing domes for PCB’s, mounting panels and DIN rails, Variable terminal compartments can be sealed off by means of dividing panels, front panels, max. 3mm thick can be fitted, No pre-punchings, smooth external surfaces for individual design of cable inlets and connections, wall assembly via integrated 4-point wall mounting system or with wall brackets. Can be fitted on DIN rail, can be used with 4 different lids. BCD 250 OT-G-..., BCD 250 FO-..., BCD 250 FO-K..., and BCD 250 OT-F... Depending on which lid is used ingress protection IP 40 to IP 65 can be achieved.
Including: 1 Base high, light gray, similar to RAL 7035
Accessories shown on drawing page.
 

Download Product Drawings For This Group  

Base, Flat

Model
 Number
Part
Number
Height Width Depth CAD
  BCD 250 UT-0.5-7035 20250235 00 8.98/228 10.24/260 1.97/50

The flat base available in light gray, can be combined with different front elements. The flat base has the following features: PCB slots, fixing domes for PCB’s, mounting panels and DIN rails, Variable terminal compartments can be sealed off by means of dividing panels, front panels, max. 3mm thick can be fitted, No pre-punchings, smooth external surfaces for individual design of cable inlets and connections, wall assembly via integrated 4-point wall mounting system or with wall brackets. Can be fitted on DIN rail, can be used with 4 different lids. BCD 250 OT-G-..., BCD 250 FO-..., BCD 250 FO-K..., and BCD 250 OT-F... Depending on which lid is used ingress protection IP 40 to IP 65 can be achieved.
Including: 1 Base flat, light gray, similar to RAL 7035
Accessories shown on drawing page.

 






 


 



 


 


 

Download Product Drawings For This Group  

Lid Hinged

Model
 Number
Part
Number
Height
Inches/mm
Width
Inches/mm
Depth
Inches/mm
CAD
BCD 250 OT-G-7035 20251035 00 9.21/234 10.39/264 1.42/36.0
BCD 250 OT-G-7024 20251024 00 9.21/234 10.39/264 4.42/36.0
The BCD 250 OT-G-... consists of a clear lid with a frame in light gray or graphite gray which contains the hinge and the snap lock mechanism. The BCD 250 OT-G-... can be opened to more that 180°, with an intermediate locking position of more that 90°. This prevents the frame from closing in an uncontrolled manner. Depending on the type of base used Ingress Protection up to IP 65 can be achieved.
7035 = Light gray 7024 = Graphite gray
Including: 1 lid hinged, 1 catch, 1 blind plug
Accessories shown on drawing page.


 

Download Product Drawings For This Group  

Terminal Compartment Lid

Model
 Number
Part
Number
Height
Inches/mm
Width
Inches/mm
Depth
Inches/mm
CAD
BCD 250 KRD-7035 20252035 00 2.40/61 9.96/253 0.79/20.0

BCD 250 KRD-7024 20252024 00 2.40/61 9.96/253 0.79/20.0

The terminal compartment lid is available in light gray or graphite gray and has an area recessed by 1.5mm to hold front membranes or membrane keypads. The cover closes the terminal compartment after the base has been divided. The terminal compartment can be arranged on the hinged side or the locking side, as required.
7035 = Light gray 7024 = Graphite gray
Including: 1 terminal compartment lid, 2 screws
Accessories shown on drawing page.


Download Product Drawings For This Group  

Front Frame Open

Model
 Number
Part
Number
Height
Inches/mm
Width
Inches/mm
Depth
Inches/mm
CAD
BCD 250 FO-7035 20251135 00 9.17/233 10.39/264 0.75/19.0

BCD 250 FO-7024 20251124 00 9.17/233 10.39/264 0.75/19.0

The BCD 250 FO-... is used for edge covering of a continuous front panel on the base. Ingress Protection IP 40 is achieved with the front panel and the appropriate base.
7035 = Light gray 7024 = Graphite gray
Including: 1 front frame
Accessories shown on drawing page.


 

Download Product Drawings For This Group  

Front Frame Open With Terminal Compartment Cover

Model
 Number
Part
Number
Height
Inches/mm
Width
Inches/mm
Depth
Inches/mm
CAD
BCD 250 FO-K-7035 20251235 00 9.17/233 10.39/264 0.75/19.0

BCD 250 FO-K-7024 20251224 00 9.17/233 10.39/264 0.75/19.0

The BCD 250 FO-... is used for edge covering of a front panel and a terminal compartment in the base. The terminal compartment section has an area recessed by 1.5mm to hold front membranes or membrane keypads. Ingress Protection IP 40 is achieved with the front panel and appropriate base.
Including: 1 front frame with terminal compartment cover, screws, screw covers.
Accessories shown on drawing page.

 

Download Product Drawings For This Group  

Membrane Lid

Model
 Number
Part
Number
Height
Inches/mm
Width
Inches/mm
Depth
Inches/mm
CAD
BCD 250 OT-F-7035 20251335 00 9.17/233 10.39/264 0.79/19.0

BCD 250 OT-F-7024 20251324 00 9.17/233 10.39/264 0.79/19.0

The BCD 250 OT-F-... is a closed membrane lid. It has an area to hold front membranes and membrane keypads. With the appropriate base, Ingress Protection IP 65 can be achieved.
7035 = Light gray, similar to RAL 7035 7024 = Graphite gray, similar to RAL 7024
Including: 1 membrane lid, screws, screw covers
Accessories shown on drawing page.


 
Note: Dimensions are external. Metric is the primary dimension. Inch conversions are for the user’s convenience and are for reference only.

We have attempted to present the information about our enclosures on this website in a straight-forward manner. We offer this information as accurate at the time of publication. Specifications are subject to change without notice. Rose+Bopla Enclosures is not responsible for inadvertent errors.  

©2008 Phoenix Mecano Inc., 7330 Executive Way, Frederick, MD 21704, 301-696-9800, rbinfo@pm-usa.com